+33 6 52 81 47 39 [email protected] Mon-Fri 08:00-18:00 (CET)
Viscom X Ray Inspection

Viscom X Ray Inspection

Browse technical resources about OPGW, ADSS, distribution automation, relay protection, fiber sensing, substation networks, line monitoring, and energy internet.

  • Inspection after installation of the distribution box

    Inspection after installation of the distribution box

    A distribution board inspection is the best way to ensure your electrical system is operating safely and reliably. Ensure safe placement: install in dry, accessible areas with good ventilation and at appropriate height (typically ~1. This prevents malfunctions, fire hazards, and unexpected power outages in your. To ensure that the electrical testing & pre-commissioning of the control, distribution, and miscellaneous panel are carried out in a manner that is risk-free, productive, and in accordance with good working practice, as required by the project work specifications. Look for any signs of burnt or damaged wiring. Additionally site team will need detailed information of all aspects associated with the installation process in order to complete the job inline with the.


  • Inspection of non-destructive optical cables

    Inspection of non-destructive optical cables

    X-ray inspection is essential for non-destructive analysis of cable interiors. Standard electrical continuity tests may fail to detect broken wires if the severed ends remain in contact due to the cable's position or bending. Defects such as thinning of the semiconducting sheaths, or of the bulk insulation, can be. Here, a terahertz (THz) frequency-modulated-continuous-wave non-destructive testing (NDT) imaging system is used to demonstrate the non-contact detection of a high-voltage cable (35 KV). However, these connections are unstable and prone to failure when the. Non- Destructive Testing (NDT/ NDT testing) Techniques or Methodologies allow the investigator to carry out examinations without invading the integrity of the engineering specimen under observation while providing an elaborate view of the surface and structural discontinuities and obstructions. The. A non-destructive test method for evaluating a synthetic rope made of strength member elements includes: treating at least one strength member element to be detectable by a magnetic NDT device, incorporating the at least one treated strength member element into the rope, scanning the synthetic rope.

    [PDF Version]
  • Relay Protection Tester Inspection Time

    Relay Protection Tester Inspection Time

    Protective circuit functional testing, including lockout relay testing, must take place immediately upon installation, every 2 years thereafter, and upon any change in wiring. THEY SHOULD BE GIVEN FIRST LINE MAINTENANCE ATTENTION. ” relay may only need to operate for 0. But failure to operate as intended can result in extensive damage, extended power outages, and loss of life. NETA. The testing and verification of relay protection devices can be divided into four groups: Type tests are needed to prove that a protection relay meets the claimed specification and follows all relevant standards. Acceptance tests fall into two categories : (i) On new relays which are to be used for the first time. Features: Durable with no moving parts, ideal for modern grids.


  • Inspection of the switch in the three-level distribution box

    Inspection of the switch in the three-level distribution box

    Starting from the wiring of low voltage command and signal cables, filling CBs with SF6 gas, special attention is given to testing and commissioning checks (visual, mechanical, electrical, operational and insulation resistance). The instructions included in this manual are provided to aid in obtaining long and economical service from your switchboards. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E, NOM-029-STPS-2011, or CSA Z462. But like any piece of electrical infrastructure, its safety and efficiency depend on regular maintenance and correct testing. The following are the safety requirements for a three-phase switch: Installation location: The three-phase switch should be. The three-level distribution system refers to a system that distributes electric power through three levels of distribution devices from the incoming power line at the construction site to the electrical equipment. The following is a detailed introduction about it: - **First-level Distribution.

    [PDF Version]
  • Inspection of Photovoltaic DC Combiner Box

    Inspection of Photovoltaic DC Combiner Box

    This inspector's guide provides practical, checklist-based frameworks for verifying solar combiner box compliance against both UL and IEC standards. Solar combiner boxes serve as critical safety junctions in photovoltaic systems, consolidating DC current from multiple solar panel strings before routing power to inverters or battery systems. Despite their relatively simple function, these enclosures are among the most scrutinized components. Photovoltaic power station com g voltages and current are present in the combiner boxes. Ideally,test in full,stable sunlight. Usually,a minimum stable irradiance of 50 W/m2 will allow for accurate comparisons among strings. These rules keep your system safe and legal. Here are some important codes and what they mean: Fuses or breakers must be tested under these standards. DC. We do a lot of solar PV and renewable energy asset inspections here at HelioVolta and SolarGrade! Every time we visit a site, we use the SolarGrade platform to guide our workflow and document our findings.

    [PDF Version]
  • Fiber Optic Cable Inspection Qualification

    Fiber Optic Cable Inspection Qualification

    Fiber testing standards from IEC, TIA, and FOA provide the technical details you need for reliable performance and certification. Note: Always check with your local authority before starting a project. Local codes may have unique requirements that go beyond national standards. Adopt smart workflows with digital tools and automation to improve efficiency, maintain clear documentation, and reduce errors during fiber testing. Existence of a standard shall not preclude any member or nonmember of NECA or FOA from specifying or using. FOA specialist training and certifications are available in three categories, Skills-based, Applications-based and Fiber optic network design. Skills-based certifications are those involving hands-on process related to the installation of fiber optic networks such as outside plant (OSP). HOLIGHT Fiber Optic applies standardized testing procedures across its passive fiber-optic components to support reliable telecom engineering practices. Fiber cable quality is evaluated across multiple dimensions: Each parameter requires a specific test method and acceptance threshold.

    [PDF Version]
  • OPGW Optical Cable Arrival Inspection

    OPGW Optical Cable Arrival Inspection

    Key OPGW testing methods include visual inspection, OTDR testing, optical power meter testing, continuity tests, and various mechanical and environmental tests. Each method targets a specific aspect of cable performance and safety. Testing OPGW cables is a multi-step process. Environmental tests are equally important. With 150 years of experience, Prysmian has been established as a leader in the energy transition and digital transformation. - GENERAL In general. Testing an Optical Ground Wire (OPGW) cable is crucial to ensure its integrity and performance, particularly because it combines the functions of grounding and optical communication. Visual Inspection Purpose: To detect any physical damage. In principle, the tension pay-off method is adopted. Every. OPGW is one of the most reliable fiber optic medium for the telecom service providers, ISPs, Cable TVs, or other organizations who are involved in the transmission of one or more form of voice, data, video, text, messages, conferencing and telemetering kind of things. Installation became widespread.

    [PDF Version]
  • What are the standalone ray tracing processing modules

    What are the standalone ray tracing processing modules

    Ray Tracing is a very computationally intensive technique. Movie makers have traditionally relied on vast numbers of CPU based render farms that still can take multiple days to render complex special effects.


  • Dimension Handheld Wireless Fiber Optic Endface Inspection Instrument

    Dimension Handheld Wireless Fiber Optic Endface Inspection Instrument

    Dimension EasyGet Wifi is a real wireless fiber endface inspection solution, it transfers real-time videos or images via Wifi (or USB) to intelligent terminals. Field technicians can visually check the fiber endface on their mobile devices. Since contamination or damage to the fiber end face can lead to signal attenuation, reflection loss, and unreliable connections, regular inspection and cleaning of the fiber end. Dimension AutoGet Wifi is industry's first foldable, all in one handheld endface microscope. Battery cover: Used to replace the battery. Light switch: Used for. The DIMENSION Handheld Fiber End Face Detector EASYGET WIFI Standard U8 is a cutting-edge, portable solution for inspecting fiber optic connectors. Ideal for professionals in the.


Need Product Pricing?

Contact us for competitive quotes on any of our power communication and smart grid products

Get a Quote