+33 6 52 81 47 39 [email protected] Mon-Fri 08:00-18:00 (CET)
Rf Link Budget Calculation Guide

Rf Link Budget Calculation Guide

Browse technical resources about OPGW, ADSS, distribution automation, relay protection, fiber sensing, substation networks, line monitoring, and energy internet.

  • IoT-grade Passive Optical Network Anti-Catalyzing Selection Guide

    IoT-grade Passive Optical Network Anti-Catalyzing Selection Guide

    An OLT consists of three major parts: 1. Service port interface function - Provides translation between service interfaces and the TC frame interface of the PON section. 2. Cross-connect function - Provides a c.


  • Substation guide optical cable

    Substation guide optical cable

    Comprehensive guide for SCADA fibre optic cable selection in substations & BESS. Hi, my name's Pete Suttmeier with Lightera Specialty Solutions division in Avon, Connecticut. Abstract: The design, installation, and protection of wire and cable systems in substations are covered in this guide, with the objective of minimizing cable failures and their consequences. Printed in the United States of America.


  • Selection Guide for SFP Industrial Switches for Field Operations

    Selection Guide for SFP Industrial Switches for Field Operations

    This guide provides a practical, standards-based approach to selecting managed industrial Ethernet switches and designing robust OT networks. Industrial ethernet switches operate from -40°C to +75°C, resist vibration and EMI, and use DIN-rail mounting — features office switches simply do not have. PoE and fiber. To overcome the barriers caused by different protocols, the International Electrotechnical Commission (IEC) developed IEC 61850, which provides a standard communication protocol for electrical substations and power grid automation. They are robust, impact-resistant and temperature-resistant. Unmanaged switches are the simplest active network. Industrial SFP modules are available in several types, including Gigabit fiber SFP, Fast Ethernet SFP, copper SFP, and BiDi SFP, allowing them to support a wide range of industrial networking architectures. Depending on the model, they can deliver transmission distances from a few hundred meters to.

    [PDF Version]
  • Smart Selection Guide for Industrial-Grade Optical Switches for Intelligent Buildings

    Smart Selection Guide for Industrial-Grade Optical Switches for Intelligent Buildings

    Mechanical Optical Switches: Switching times typically range from 1-10ms, suitable for long-distance transmission scenarios where latency is not critical (such as backbone network protection switching). Solid-State Optical Switches: Based on thermooptic or electrooptic effects, response time can be. OPTO-TOUCH Optical Touch Buttons are zero-force ergonomic replacements for mechanical push buttons. Momentary-action touch buttons with electromechanical relay or solid-state outputs. 2 dB), fastest switching speed (10 ns), broadest wavelength range (300–2400 nm), widest fiber compatibility, highest optical power handling (50 W), and space-qualified reliability. Backed by over 25 years of. Optigo Connect Spectra is an efficient and flexible network that fits any smart building and reduces cabling cost while increasing reach.


  • Gyftzy guide optical cable

    Gyftzy guide optical cable

    Pine layer twisted non-metal flame retardant optical cable GYFTZY (2-288 core) is a type of optical fiber cable used for long-distance telecommunications and data transmission. The tubes (and fillers) are stranded around a non-metallic central strength member to form a cable core. Then, a LSZH outer jacket is extruded. This cable is specifically designed for harsh environments where traditional metal cables may corrode or be damaged. Long-haul communication, interoffice communication. GYFTZY (non-metallic strengthening member, flame retardant, loose tube layer-stranded filling type, polyethylene sheath) non-metallic flame-retardant optical cable (general power optical cable adopts layer-stranded type) is basically the same as in GYFTY, mainly based on GYFTY optical cable The. Fiber reinforced plastic central strength member, Tube filling gel, Loose tube stranded, PE sheath outdoor cable. Application Operating Temperature Water-blocking construction Moisture-proof and prevents water penetration Special filling gel in loose tubes Reduce or eliminate reflection losses and.

    [PDF Version]
  • Quick Start Guide to Cable Trays

    Quick Start Guide to Cable Trays

    This guide covers the critical steps, from selecting the right electrical cable tray and performing accurate cable fill calculations to managing a safe cable pull through and ensuring all bonding and grounding requirements are met. But before you lay the first tray or clamp down a single cable, you need a solid plan. This guide breaks down the process step by step. Need to renew your Electrician license? Pick your state and browse state-approved Electrician CE courses — complete your continuing education hours online, with instant reporting. Article Summary: A compliant cable tray installation requires a thorough understanding of NEC Article 392, proper. Here is a step-by-step guide on how to install a standard metal cable tray system (e. The Cable Tray ng standards, performance standards, test standards and application in this document have been tested extens ompetent professional en completely installed, without damage either to conductors or. Bilal Switchgear Engineering knows that a messy electrical room is a dangerous one.

    [PDF Version]
  • Electrical distribution box calculation reserve

    Electrical distribution box calculation reserve

    The calculator employs NEC Article 314. 16 formulas to determine required box volume. The basic formula is: Required Volume = (Number of Conductors × Volume per Conductor) + (Number of Devices × 2 × Volume per Conductor) + (Number of Fittings × Volume per Conductor). The information provided in this document contains general descriptions, technical characteristics and/or recommendations related to products/solutions. This document is not intended as a substitute for a detailed study or operational and site-specific development or schematic plan. It is not to be. Electro Centers or Integrated Power Assemblies (IPA) can be fitted out with a variety of electrical distribution equipment and shipped to the site in preassembled modules for mounting on elevated foundation piles, building setbacks or rooftops. Before we dive into calculations, let's get familiar with a few essentials: 1. Power Supply is 430V (P-P), 230 (P-N), 50Hz. The calculation is based on the following standard volumes: The formula is: [ text {Box Size} = (text {Number of Wires} times 2.

    [PDF Version]
  • Calculation for fabrication of horizontal elbows in cable trays

    Calculation for fabrication of horizontal elbows in cable trays

    Calculate the necessary length of material to form elbows, considering the inner radius and degree of the bend to minimize material stress. The method for producing bridge bend elbows is as follows: Take a 90-degree cable tray bend elbow as an example, and apply the same principles for 45-degree bends accordingly. The length of the bottom side (bottom diagonal) after bending the cable tray should be equal to the width of the cable. This manual is designed to guide workers through the detailed production process of ladder cable trays, including the manufacture of horizontal elbows, tees, crosses, reducing bends, and vertical bends, with emphasis on precision, safety, and quality control. A rung spacing of 6 to 9 inches (150 to 230 mm) is preferable when the cable tray cont d for instrumentation and control applications that require additional protec eferred to support and protect numerous small. Unitray Systems Inc. is an Edmonton based company dedicated to excellence in the manufacturing of electrical ladder tray.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our power communication and smart grid products

Get a Quote