+33 6 52 81 47 39 [email protected] Mon-Fri 08:00-18:00 (CET)
Bus Duct  Spaceagegroup

Bus Duct Spaceagegroup

Browse technical resources about OPGW, ADSS, distribution automation, relay protection, fiber sensing, substation networks, line monitoring, and energy internet.

  • Outdoor server rack air duct heat dissipation principle

    Outdoor server rack air duct heat dissipation principle

    At the heart of server rack cooling is a basic principle: heat moves from hot to cold. This process, called thermal transfer, is how your equipment gets rid of excess heat. Rack mount equipment generates heat as a result of the processes it completes; the amount of heat a piece of equipment dissipates is approximately equal to the total electrical power delivered to it. This heat is absorbed by the ambient air in the server, and removed by airflows generated by fans. Because data centers are high-density enclosed spaces that generate a significant amount of heat, traditional comfort cooling systems can't remove enough heat to protect the critical equipment. Additionally, well-managed heat control helps systems consume less power. IT system energy efficiency. Whether you're operating industrial automation systems with electrical switchgear or high-density data servers in server racks, effective temperature management is crucial for long-term performance and equipment longevity.

    [PDF Version]
  • Low-voltage bus creepage distance

    Low-voltage bus creepage distance

    These distances are influenced by voltage level, pollution degree, and the system insulation category. The IEC 61439-1 standard is the most commonly used document for defining these values., PVC dipping, epoxy. In busbar clearances and creepage distances, the first distinction is simple but critical. It applies to low-voltage switchgear and control gear assemblies and provides a table of minimum clearances. This article provides a brief explanation of their significance and the possible faults that may arise if these. Ensuring clearances and creepage distances meet the minimum requested by the standard avoids problems for nominal voltage and overvoltage such as: Before we get into how you can meet these requirements, let's define terms: What are clearances and creepage distances in LV switchboards? What are the. Clearance - the distance between two conductive parts along a string stretched the shortest way between these conductive parts.

    [PDF Version]
  • Fiber Optic Cable Duct Detection

    Fiber Optic Cable Duct Detection

    Fiber optic sensing technology has revolutionized the way we monitor and manage buried fiber optic cables. By converting optical fibers into thousands of virtual sensors, we can detect changes in temperature, strain, and other critical parameters. Duct fiber optic cables—often called “duct fiber”—are specialized optical cables engineered to be installed within pre-existing ducts (hollow tubes) rather than buried directly in soil or strung from poles. What can be detected is the cable strengthening, the jacket, the trenching, the ducts they are in and if included. Fiber optic cable is a type of cabling that contains one or more optical fibers for transmitting data at high speeds and/or over long distances using light. These fibers are most commonly made of glass and are very thin, typically less than a tenth of the width of a human hair. Any such damage may alter the cable's characteristics to the extent that the cable section may have to be replaced. To ensure all specifications are met, consult the specific cable specification sheet for the cable you. DNV is a leader in verifying distributed fibre-optic sensing (DFOS) systems for pipeline leak detection.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our power communication and smart grid products

Get a Quote